B3EI04K1 - 607
DRAINING - FILLING - BLEEDING HYDRAULIC CIRCUIT
1 - PRECAUTIONS TO BE TAKEN
WARNING : carry out the operation with care in order to prevent the entry of contaminating particles .
Use new fluid when filling and topping up the system .
Draining the hydraulic circuit must be performed with :
2 - DRAINING
Remove the filler cap .
Remove the shield under the power train (according to specification) .
Remove the bolt (1) .
Remove the clamp (2) .
WARNING : take care not to damage the valve .
Direct the pipes into a container .
Turn the steering slowly from lock to lock in each direction .
Wait for the fluid to finish draining .
3 - REFILLING
Refit the new seals (3) .
Fit :
Tighten the bolt (1) to 2 da.Nm .
Refit the shield under the power train (according to specification) .
IMPERATIVE : use new fluid when filling and topping up the system .
Fill the power steering reservoir 10 to mm above the maximum mark (A) .
With the engine stopped, Turn the steering slowly from lock to lock in each direction : Approximately 10 times .
Again fill the reservoir up to the maximum level (A) .
4 - BLEEDING
Run the engine at idle for 2 to 3 minutes without moving the steering wheel .
Keep the fluid level topped up .
Bleed the circuit by turning the steering several times in each direction .
Keep the fluid level topped up .
(A)Maximum level .
The level must be set with the engine stopped and the wheels straight ahead .