C5HG1BF1 - 607
REMOVAL - REFITTING COMPRESSOR
IMPERATIVE : before any work on the air conditioning circuit, observe the recommended precautions .
1 - SPECIAL TOOLS
[1] Air conditioning maintaining equipment : Approval number FAC.18.08 .
2 - REMOVAL
Drain the refrigerant circuit : Using the tool [1] .
Remove :
EW12J4 ENGINE
remove the ancillary drive belt .
ES9J4S ENGINE
remove the ancillary drive belt .
DW12TED4 ENGINE
remove the ancillary drive belt .
DW10ATED ENGINE DW12TED4 ENGINE
ES9J4S ENGINE EW10J4 ENGINE EW12J4 ENGINE
ALL MODELS
Remove the bolt (1) .
Remove the clamp (2) .
IMPERATIVE : quickly seal the compressor inlets and outlets and the pipes .
DW10ATED ENGINE DW12TED4 ENGINE
ES9J4S ENGINE
EW10J4 ENGINE EW12J4 ENGINE
ALL MODELS
Disconnect the compressor connector (4) .
Remove the 4 mounting bolts (3) from the compressor .
Remove the compressor .
3 - REFITTING
DW10ATED ENGINE DW12TED4 ENGINE
NOTE : for the DW engine, refit the compressor, observing the above sequence of assembly of parts .
ALL MODELS
Tighten the fasteners to the correct torque starting with the two fasteners on the pulley side (Tightening torque 4.5 da.Nm) .
Remove the blanking pieces placed in the compressor and the pipes .
Fit the clamp (2) (Tightening of the bolt (1) to 4 daN.m) .
Fit the ancillary drive belt .
EW12J4 ENGINE
fit the ancillary drive belt .
ES9J4S ENGINE
fit the ancillary drive belt .
DW12TED4 ENGINE
fit the ancillary drive belt .
ALL MODELS
Fill the refrigerant circuit with the correct charge for the vehicle : Using the tool [1] .
Check the operation of the refrigerant circuit .