C5HG06K1 - 607 CLIMATE CONTROL
REMOVAL - REFITTING COMPRESSOR DRIVE PULLEY
1 - TOOLING
[1] Extractor (-).0174 .
2 - REMOVAL
precautions to be taken .
Remove :
Fit the extractor [1] .
Extract the compressor drive pulley .
3 - REFITTING
Fit the pulley and push it fully home .
Fit :
Fit the old nut and tighten it to 3.5 to 4 da.Nm .
Check and adjust the air gap .
Fit a new nut in place of the old one .
Tighten it to 3.5 to 4 da.Nm .