C5HG08F1 - 607
REMOVAL - REFITTING HEATER
IMPERATIVE : BEFORE ANY WORK ON THE AIR CONDITIONING CIRCUIT, OBSERVE THE RECOMMENDED PRECAUTIONS .
1 - SPECIAL TOOLS
[1] Hose clamp : Workshop reference (-).1512 .
2 - REMOVAL
Drain the refrigerant circuit .
Remove the fascia .
Remove the ventilator conduits .
Unclip the scuttle panel .
Remove the pollen filter .
Remove the 2 fittings (1) from the filter bracket (2) .
Depressurise the cooling system .
Clamp the heater matrix inlet and outlet pipes (3), Using the tool [1] .
Disconnect the hoses (3) .
Remove the fastener (4) .
Remove the nuts (5) .
Detach the clamp from the pressure relief valve and block the input points of the pressure relief valve and the pipes .
Remove the 2 fittings (6) from the heater assembly on the bulkhead .
Remove the fittings (7) from the condensation drain plate (8) .
Disconnect the connector (9) from the blower module, Release the harness .
WARNING : place a receptacle under the heater matrix inlet and outlet pipes .
Remove the heater assembly .
3 - REFITTING
Proceed in the reverse order to removal .
Fit new lubricated seals on all the pipes of the air conditioning circuit which have been removed. .
Check operation of the circuit .