C5HH05F1 - 607

REMOVAL - REFITTING DEHYDRATOR FILTER

IMPERATIVE : BEFORE ANY WORK ON THE AIR CONDITIONING CIRCUIT, OBSERVE THE RECOMMENDED PRECAUTIONS .

1 - TOOLING

[1] Torx adaptor T70 (-).9776-X2 .

2 - REMOVAL

Drain the air conditioning circuit .

Remove :

Remove the cap (1) from the condenser using tool [1] .

Replace the dehydrator filter .

Tightening torque of the cap (1) : 1.4 da.Nm .

3 - REFITTING

Proceed in the reverse order to removal .

Clean the thread of the cap (1), as well as the threaded area of the reservoir using a lubricated antistatic cloth .

Lubricate the seals of the cap using compressor oil .

RECHARGE WITH REFRIGERANT .

Check the operation of the refrigerant circuit .