C5HH05F1 - 607
REMOVAL - REFITTING DEHYDRATOR FILTER
IMPERATIVE : BEFORE ANY WORK ON THE AIR CONDITIONING CIRCUIT, OBSERVE THE RECOMMENDED PRECAUTIONS .
1 - TOOLING
[1] Torx adaptor T70 (-).9776-X2 .
2 - REMOVAL
Drain the air conditioning circuit .
Remove :
Remove the cap (1) from the condenser using tool [1] .
Replace the dehydrator filter .
Tightening torque of the cap (1) : 1.4 da.Nm .
3 - REFITTING
Proceed in the reverse order to removal .
Clean the thread of the cap (1), as well as the threaded area of the reservoir using a lubricated antistatic cloth .
Lubricate the seals of the cap using compressor oil .